Coax cable loss
How much signal your cable costs
Every metre of coax costs you a little bit of signal, on transmit and on receive. On HF that loss is usually small, but on VHF and UHF the choice of cable makes a real difference. This page lists the attenuation of the 50 Ω cables you come across most often in the shack. To choose a matching connector, see RF connector types.
Table of Contents
Attenuation compared
All figures are typical values in dB per 100 metres at 20 °C, taken from the datasheets of SSB‐Electronic, which list RG‐58 and RG‐213 alongside their own cables.
| Cable | Outer diameter | Velocity factor | 10 MHz | 100 MHz | 500 MHz | 1000 MHz |
|---|---|---|---|---|---|---|
| RG‐58 | approx. 5 mm | 0.66 | 5.0 | 17.0 | 39.0 | 54.6 |
| H155 | 5.4 mm | 0.80 | 3.2 | 9.1 | 20.0 | 29.6 |
| Aircell 7 | 7.3 mm | 0.85 | 2.1 | 6.0 | 14.0 | 20.4 |
| RG‐213 | approx. 10.3 mm | 0.66 | 2.0 | 7.0 | 17.0 | 22.5 |
| Ecoflex 10 Plus | 10.2 mm | 0.85 | 1.1 | 3.8 | 9.1 | 13.5 |
| Aircom Premium | 10.2 mm | 0.85 | 1.1 | 3.4 | 8.1 | 11.9 |
| Ecoflex 15 | 14.6 mm | 0.85 | 0.9 | 2.8 | 6.7 | 9.8 |
On the amateur bands
For the cables with complete datasheets, these are the figures on the bands where it matters most (dB per 100 m):
| Cable | 10 MHz | 144 MHz (2m) | 432 MHz (70cm) | 1296 MHz (23cm) |
|---|---|---|---|---|
| H155 | 3.2 | 10.6 | 18.7 | 33.9 |
| Aircell 7 | 2.1 | 7.2 | 12.9 | 23.6 |
| Ecoflex 10 Plus | 1.1 | 4.7 | 8.5 | 15.7 |
| Aircom Premium | 1.1 | 3.9 | 7.2 | 13.4 |
| Ecoflex 15 | 0.9 | 3.4 | 6.1 | 11.4 |
What does that mean in practice?
The loss scales with the length, so 20 metres has one fifth of the loss in the table. Every 3 dB halves the power.
- 20 m of Aircell 7 on 70cm: 12.9 × 0.2 = 2.6 dB, so of 50 watts only about 28 watts reaches the antenna.
- The same 20 m of Ecoflex 10 Plus: 8.5 × 0.2 = 1.7 dB, leaving about 34 watts.
- 25 m of RG‐58 on 30m (10 MHz): 5.0 × 0.25 = 1.25 dB. That’s about 25% of your power, which on HF is often acceptable for a portable setup.
The loss on receive is the same, which matters most on the higher bands where noise from the receiver itself starts to count.
Keep in mind that these figures apply to a matched line. A high SWR adds extra loss in the cable, more so as the cable is longer and lossier (see SWR and return loss). Old cable with water in it can be much worse than the datasheet.
Velocity factor and electrical length
A signal travels more slowly through coax than through free space. The velocity factor tells you how much: 0.66 for cables with solid PE insulation such as RG‐58 and RG‐213, about 0.85 for cables with foam PE such as Aircell and Ecoflex. That matters whenever a piece of coax has to be a specific electrical length, for example for a stub, a phasing line or a coax balun.
A quarter wavelength of coax is:
length (m) = 75 / frequency (MHz) × velocity factor
| Band | Frequency | λ/4 with VF 0.66 | λ/4 with VF 0.85 |
|---|---|---|---|
| 40m | 7.1 MHz | 6.97 m | 8.98 m |
| 20m | 14.2 MHz | 3.49 m | 4.49 m |
| 10m | 28.5 MHz | 1.74 m | 2.24 m |
| 2m | 145 MHz | 0.341 m | 0.440 m |
| 70cm | 435 MHz | 0.114 m | 0.147 m |
The velocity factor in datasheets is a typical value, so cut a stub slightly long and trim it while measuring with an antenna analyser.
Choosing a cable
- Portable and short runs on HF: RG‐58 or H155 are light and flexible.
- The shack and runs up to about 20 m: Aircell 7 is a good all‐rounder, also for 2m and 70cm.
- Longer runs or VHF/UHF: Ecoflex 10 or Aircom Premium.
- Long runs on UHF and higher: Ecoflex 15 or rigid hardline.